MDSI 7096 one component Silicone adhesive 

  • Neutral alkoxy curing system
  • Good compatibility with Pt catalytic system
  • Paste does not hang
  • No bottom coating adhesive performance is good
  • Good continuous thermal stability (-55-200℃)
  • Good high temperature electrical insulation

MDSI 7096 Dealcoholized silicone bonding sealant is a neutral silicone sealing material that absorbs moisture in the air to cure at room temperature, and cannot be heated to cure.

Appearance Visual Unit 7096 7096
Appearance Visual White/Black Yellow translucent
Viscosity GB/T 2794-2022 Paste Paste
Tack-free Time GB/T13477.5-2002 min ≤30 10-40
Hardness GB/T 531.1-2008 Shore A 20±3 20±3
Density GB/T 13354-1992 g/cm3 1.33±0.03 1.05±0.05
Elongation at break GB/T 528-2009 % ≥250 ≥250
Anti-toxicity See note 2 Fully cured Fully cured
Tensile strength GB/T 528-2009 Mpa ≥1.0 ≥1.0
Shear strength GB/T 7124-2008 Mpa, Fe/Fe 2.2 ≥0.90
Tear strength GB/T 529-2008 N/mm 7 7
Dielectric strength GB/T 1693-2007 kV/mm(25℃) 18 18
Loss factor GB/T 1693-2007 (1MHz) (25℃) 0.001 0.001
Dielectric constant GB/T 1693-2007 (1MHz) (25℃) 2.9 2.8
Volume resistance GB/T 1692-2008 (DC500V) Ω· cm ≥5.0*1014 ≥5.0*1014

MDSI 7096 is mainly designed to protect the non-curing phenomenon caused by the failure of the passive catalyst of the additive potting-sealant. 7096 is used to do the isolation of toxic sources, including possible materials: PVC/ peroxide-vulcanized rubber, anti-aging agents containing sulfur phosphorus nitrogen elements, unsaturated polyester, tin lead and other organometall catalysts.

Operation process

  • Clean the surface: the surface of the sticky or coated material is cleaned, and the rust, dust and oil are removed with cleaning agent.
  • Sizing: Cut the nozzle to the required size and load it into the glue gun. Squeeze the glue solution onto the cleaned surface for an even distribution. When bonding, the adhesive surface can be closed and fixed.
  • Solidification: the coated part is placed in the air, and can be put into use after 24 hours of room temperature curing.
  • Note: After opening, use it up as much as possible once, once not used up, when using again, squeeze out the cured part, continue to use, does not affect normal use.
  • Please consult MDTECH Marketing Department for dispensing equipment.